Three Phase Output Reactor compatible to ALSTOM Inverter
The output reactor is used with an inverter to be connected to a motor by a long cable. It has the functions of decreasing peak voltage and current, and smoothing pulse width modulated waveform. The conventional output choke usually has desirable storage capacity.
Technical Parameter
Source Voltage V | Power V
| ALSTOM Inverter | Three Phase Output Reactors | ||||
Model | Input Current A | Output Current A | Current A | ALSTOM Ordering No. | HSLEC Ordering No. | ||
3AC 400~415 | 18.5 | 22/27-400 | 43 | 40 | 80 | 29153811 | HSL220-AL201 |
22 | 27/33-400 | 51 | 48 | ||||
30 | 33/43-400 | 65 | 62 | ||||
37 | 43/54-400 | 82 | 78 |
More information, welcome to contact with me.
Functions
1. The output reactor is able to extend the lifetime of output motor.
2. It can also dampen overshoot peak voltage.
3. The low voltage reactor is used to reduce motor heating and audible noise.
Features
1.To add line impendence
2.To provide some light buffering against low magnitude line spikes
3.To reducing harmonics
4.To compensating for a low inductance motor
5.Only as part of a filter for reflected wave reduction
Customer Benefits
High harmonic stress resistance
Very low losses
Low noise
Long operating life expectancy
Packing
Protected by Water-Repellent Cloth, Secured and Packed in Wooden Case
Delivery Time
10-30 Days Depending on Quantity Ordered
Welcome to Huashenglong low voltage reactor! The line reactor, output reactor shown here, are compatible to France ALSTOM frequency DC speed governor. We provide a variety of line reactor and output reactor to suit many series, such as Mv1000, Md2000, and WNTC series ALSTOM frequency DC speed governor. Operating at the same source voltage of 3AC380~480V, the HSL119-AL21 three phase line reactor is compatible with 29203347 ALSTOM transformer, while HSL220-AL01 three phase output reactor is used to work together with 29203376 ALSTOM transformer. We also have reactor compatible to ALSTOM transformer, with the source voltage of 3AC400~415V.