Product Detailed
Three Phase Reactor compatible to ALSTOM Inverter 1.Source Voltage:3AC380~480V 2.Motor Power:0.75~45kW 3.Current:7~90A 4.3-P

Three Phase Reactor compatible to ALSTOM Inverter 

The output reactor is used with an inverter to be connected to a motor by a long cable. It has the functions of decreasing peak voltage and current, and smoothing pulse width modulated waveform. The conventional output choke usually has desirable storage capacity.

Technical Parameter

Source Voltage (V)

Power(V)

ALSTOM Inverter

Three Phase Output Reactors

Model

Input Current A

Output Current A

Current A

ALSTOM Ordering No.

HSLEC Ordering No.

3AC380~480

0.75

Mv103

2.5

2.5

7

29203376

HSL220-AL01

1.5

Mv104

3.9

3.9

3

Mv107

7

7

5.5

Mv1013

12

13

24

29203377

HSL220-AL02

7.5

Mv1018

15.5

17.5

11

Mv1024

20.5

23.5

15

Mv1032

27

32

47

29203378

HSL220-AL03

22

Mv1047

42

47

30

Mv1059

53

59

90

29203379

HSL220-AL04

45

Mv1089

78

89

More  information, welcome to contact with us.

Functions

1. The output reactor is able to extend the lifetime of output motor.

2. It can also dampen overshoot peak voltage.

3. The low voltage reactor is used to reduce motor heating and audible noise.

Packing

Protected by Water-Repellent Cloth, Secured and Packed in Wooden Case

Delivery Time

10-30 Days Depending on Quantity Ordered

Welcome to low voltage reactor of Huashenglong, who specializes in manufacturing line reactor and output reactor that are compatible to France Schneider soft starter and inverter. We have a range of line reactor and output reactor specially used for ATS, ATV38 and ATV31 series of Schneider soft starter and inverter. For example, the HSL119-S01 three phase line reactor is compatible with the VZ1-L015UM17T Schneider soft starter. Working in 3AC 400~500V system, HSL119-SL01 three phase line reactor is designed for VW3 A66501 Schneider inverter. With the same working voltage of 3AC 400~500V, the HSL220-SL01 three phase output reactor can work together with VW3 A68504 Schneider inverter.

Three Phase Reactor compatible to ALSTOM Inverter